TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0353 03
Tilt Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Voltage Above
that the voltage for the tilt lever position sensor is too high. The signal
Normal or Shorted High
wire for the tilt lever position sensor connects to connector contact J2-
25 (wire H711 GN) of the implement ECM. The tilt lever position
sensor is a 500 Hz PWM sensor. The possible causes are the signal
circuit is shorted to the +battery circuit, the sensor has failed, the signal
circuit is open, or the ground circuit is open. When this code is
generated, the tilt function will be disabled until the diagnostic code is
cleared and the tilt lever must be recentered.
0353 04
Tilt Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Voltage Below
that the voltage for the tilt lever position sensor is too low. The tilt lever
Normal or Shorted Low
position sensor is a PWM sensor. The possible causes are the harness
between the implement ECM and the sensor has a short to ground, the
sensor has failed, or the + battery circuit has an open. When this code
is generated, the tilt function will be disabled until the diagnostic code
is cleared and the tilt lever must be recentered.
0353 08
Tilt Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Abnormal
that the signal for the tilt lever position sensor has an abnormal pulse
width, abnormal frequency, or an abnormal period. The tilt lever
Period
position sensor is a PWM sensor. The signal wire for the tilt lever
position sensor connects to connector contact J2-25 (wire H711 GN) of
the implement ECM. The possible causes are the circuit for the +battery
to the sensor has a intermittent connection, the return circuit from the
sensor has a intermittent connection, the signal circuit from the sensor
has a intermittent connection, or the sensor has failed. The tilt function
will not operate while the diagnostic code is active.
0353 13
Tilt Lever Position
This diagnostic code is recorded when the implement ECM determines
Sensor Out of
that the tilt lever position sensor is out of calibration. The tilt lever
position sensor is a PWM sensor. One possible cause is the tilt lever
has operated outside the calibrated range for more than three seconds.
When this code is generated, implement features will not operate and
the lever will operate with increased deadband.
0007 00-34