TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(d) Observe status of diagnostic code.
1. If diagnostic code is inactive, initial
0351 04 - Continued.
diagnostic code was probably caused by
poor electrical connection or short at
wiring harness connector that was
disconnected and then reconnected.
Resume normal machine operation.
2. If diagnostic code is active, exit this
diagnostic code and repeat this
procedure. If cause of diagnostic code is
not found, then replace implement ECM
(WP 0060 00).
427-C1653
N OT E
0351 08
Ensure CID 0351 FMI 08 is active and diagnostic code indicator is
active.
sensor.
(a) Observe ON/OFF status of
diagnostic code indicator.
(b) Disconnect wiring harness from
1. If diagnostic code indicator is active, go
sensor (WP 0089 00).
to Test 2.
2. If diagnostic code indicator is inactive,
replace sensor (WP 0089 00).