Table 4. Implement Control - Continued.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  710    711    712    713    714  715  716    717    718    719    720  
img
.
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check wiring harness.
0354 03 - Continued.
(a) Turn engine start switch to OFF
position (TM 5-3805-291-10).
(b) Disconnect wiring harness from
implement ECM (WP 0060 00).
(c) Turn engine start switch to ON
position (TM 5-3805-291-10).
(d) At wiring harness connector for
1. If voltage is approximately battery
implement ECM, measure voltage
voltage, replace wiring harness in
between contact J1-50 (wire H716-
question (WP 0195 00 thru WP 0201 00).
WH) and contact J1-48 (wire
2. If voltage is approximately 0 DCV, go to
H713-PK).
Test 3.
3. Ensure diagnostic code remains active.
(a) Turn engine start switch to OFF
position (TM 5-3805-291-10).
(b) Disconnect and inspect all wiring
harness connectors and reconnect.
Refer to Electrical Connectors
Inspection (WP 0022 00) as
necessary.
(c) Turn engine start switch to ON
position (TM 5-3805-291-10).
(d) Operate machine. Use messenger to 1. If diagnostic code is active, exit this
ensure same diagnostic code is
procedure and repeat this test procedure.
active (TM 5-3805-291-10).
If cause of diagnostic code is not found,
replace implement ECM (WP 0060 00).
2. If diagnostic code is not active, initial
diagnostic code was probably caused by
a poor electrical connection wiring
harness connector that was disconnected
and reconnected. Resume normal
machine operation.
0009 00-206