Table 4. Implement Control - Continued.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  712    713    714    715    716  717  718    719    720    721    722  
img
.
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Reconnect solenoid valve to wiring
0354 05 - Continued.
harness.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
(e) At wiring harness connector for
1. If resistance is greater than 5,000 Ohms
implement ECM, measure
(no continuity), wiring harness circuit
resistance between contacts J1-50
has failed. Replace wiring harness in
(wire H716-WH) and contact for
question (WP 0195 00 thru WP 0201 00).
failed solenoid J1-48 (wire H713-
2. If resistance is from 6 to 12 Ohms, exit
PK).
this test and repeat test. Also, ensure
diagnostic code indicator is active for this
diagnostic code. If cause is not found,
replace implement ECM (WP 0060 00).
427-C1656
N OT E
0354 06
The following procedure may create other diagnostic codes. Ignore created diag-
nostic codes. Clear these diagnostic codes when optional diagnostic code has
been corrected.
Ensure diagnostic code is active and diagnostic code indicator is active.