TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(b) At wiring harness connector for
0353 08 - Continued.
sensor, connect positive lead from
(c) Turn battery disconnect and engine
start switches to ON position (TM
5-3805-291-10).
1. If PWM signal from sensor is a 500 Hz
signal between 5% and 95%, go to Test 4.
output.
2. If PWM signal from sensor is not a 500
Hz signal or signal is not between 5% and
95%, replace joystick (WP 0219 00).
4. Check if diagnostic code remains active.
(a) Disconnect, inspect, and clean all
relevant wiring harness connector
(b) Reconnect all wiring harness
connectors.
(c) Operate machine (TM 5-3805-291-
10).
(d) Use messenger to check status of
1. If CID 0353 FMI 08 is not active, initial
CID 0353 FMI 08 (TM 5-3805-
diagnostic code was probably caused by
291-10).
poor electrical connection or short at
wiring harness connector that was
disconnected and reconnected. Resume
normal machine operation.
2. If CID 0353 FMI 08 is active, exit this
procedure and repeat this procedure. If
cause of diagnostic code is not found,
replace implement ECM (WP 0060 00).
Recalibrate lever position sensor (WP 0017 1. If calibration causes this diagnostic code
0353 13
00).
to become inactive, resume normal
machine operation.
code to become inactive, connect MSD
each lever position. Refer to Table 14 in
back of this work package if cycle time
values are not correct, replace joystick
(WP 0219 00).