Table 4. Implement Control - Continued.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  705    706    707    708    709  710  711    712    713    714    715  
img
.
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(d) Use messenger to check status of
1. If CID 0353 FMI 03 is not active, initial
0353 03 - Continued.
CID 0353 FMI 03 (TM 5-3805-
diagnostic code was probably caused by
291-10).
poor electrical connection or short at
wiring harness connector that was
disconnected and reconnected. Resume
normal machine operation.
2. If CID 0353 FMI 03 is active, exit this
procedure and repeat this procedure. If
cause of diagnostic code is not found,
replace implement ECM (WP 0060 00).
427-C1655
N OT E
0353 04
The following procedure may create other diagnostic codes. Ignore these created
diagnostic codes and clear diagnostic codes when original diagnostic code is cor-
rected.
Ensure diagnostic code is active.
1. Check sensor.
Disconnect sensor from wiring harness
1. If sensor is not cause of diagnostic code,
(WP 0219 00).
go to Test 2.
2. If service code is inactive, replace
joystick (WP 0219 00).
2. Check wiring harness.
(a) Sensor remains disconnected.
(b) Turn battery disconnect switch to
OFF position (TM 5-3805-291-10).
0009 00-201