Figure 4. Tilt Cylinder.
Figure 1. Gear Pump.

Field Maintenance Manual For M400T And M400W
Page Navigation
  606    607    608    609    610  611  612    613    614    615    616  
img
. . . . . . . . . . . . . . . .
6
TM 5-3805-292-23
0088
FIELD MAINTENANCE
-
GEAR PUMP MAINTENANCE
0088
REMOVAL, DISASSEMBLY, CLEANING AND INSPECTION, ASSEMBLY, INSTALLATION
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's (WP 0178, Item
TM 5-3805-292-10
0
33)
TM 5-3805-292-23P, Figures 41, 47
0
0
SATS (WP 0178, Item 30)
0
Equipment Conditions
0
Wrench, Torque, Click, Ratcheting, 3/8 in.
ROPS tilted (WP 0134)
Drive, 75 lb-ft (contained in SATS) (WP
0
Hydraulic pressure relieved (WP 0172)
0178, Item 39)
0
0
Hydraulic reservoir drained (WP 0009)
0
Materials/Parts
0
Seat removed (WP 0126)
0
Cap Set, Protective (WP 0179, Item 2)
0
Cab cover plate removed (WP 0095)
0
Cleaning Compound, Solvent, Type III (WP
Estimated Time to Complete
0179, Item 3)
0
0
Oil, Lubricating, OE/HDO-10 (WP 0179, Item
3.0 Hr
0
16)
0
Rag, Wiping (WP 0179, Item 19)
0
Tag, Marker (WP 0179, Item 30)
0
Kit, Seal
0
O-ring (3)
0
0
WARN I N G
When servicing this machne, performing maintenance, or disposing of hazardous
i
materials, consult your unit/local hazardous waste disposal center or safety office for local
regulatory guidance. If further information is needed, please contact The Army
Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic system lines or fitting unless engine is shut
down and hydraulic system pressure has been relieved. Tighten all connections before
applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin.
At operating temperature, hydraulic oil is hot.Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
C AU T I O N
Cap all hydraulic hose and line ends along with component connections during removal to
protect against contamination. Failure to follow this caution may result in damage to
equipment.