Table 1. Kickout System Will Not Operate or Operates Improperly Continued.
Table 1. Kickout System Will Not Operate or Operates Improperly Continued.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  227    228    229    230    231  232  233    234    235    236    237  
img
. .
TM 5-3805-298-23-2
0155
Table 1. Kickout System Will Not Operate or Operates Improperly Continued.
0155
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Voltage 0.5 V or Greater Proceed to
7. Using digital multimeter
Kickout System Will Not
Test Step 43.
(WP 0174), test for voltage
Operate or Operates
between connector N-C3
Improperly - Continued
Voltage Less Than 0.5 V and Directed
terminal B (WP 0012, Figure 234)
Here From Test Step 8 Replace fork
and ground.
kickout position sensor (WP 0297).
Proceed to Test Step 60.
Voltage Less Than 0.5 V and Directed
Here From Test Step 11 Proceed to
Test Step 56.
Figure 28. Tiedown Straps.