TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0354 03
Lift Pilot Control Valve
This diagnostic code is recorded when the implement ECM detects a
Solenoid 1 Voltage
short to the +battery in the electrical path. The electrical path goes from
Above Normal or
the implement ECM to the solenoid and back to the implement ECM.
Shorted High
The return circuit is connected for all solenoids. The return circuit
connects to contacts J1-50 (wire H716 WH) of the implement ECM.
The possible causes of this diagnostic code are the signal circuit from
the implement ECM to the solenoid valve is shorted to the +battery and
the return circuit from the solenoid valve is shorted to the +battery.
When this code generated, all electro-hydraulic valves are turned off,
the pilot on/off solenoid valve is turned off, and implement functions
are disabled until the fault is corrected and the levers are centered.
0354 05
Lift Pilot Control Valve
This diagnostic code is recorded when the implement ECM detects an
Solenoid 1 Current
incomplete electrical path from the implement ECM to the solenoid and
Below Normal or Open
back to the implement ECM. The return circuit is connected for all
Circuit
solenoids. The return circuit connects to contact J1-50 (wire H716 WH)
of the implement ECM. The possible causes of the diagnostic code are:
The signal circuit fom the implement ECM
r
to the solenoid is open.
The return circuit from the solenoid is open.
An open in the return circuit may result in an
open circuit diagnostic code for all the
implement solenoid valves.
the solenoid winding is open.
When this code is generated, the lift linkage will not raise and the raise
function will be disabled until the fault is corrected and the levers are
centered.
0354 06
Lift Pilot Control Valve
This diagnostic code is recorded when the implement ECM detects a
Solenoid 1 Current
short to ground in the electrical path from the implement ECM to the
Above Normal or
solenoid. The return circuit is connected for all solenoids. The return
Grounded Circuit
circuit connects to contacts J1-50 (wire H716 WH) of the implement
ECM. The possible causes of this diagnostic code are the solenoid
winding has low impedance or is shorted and the signal circuit from the
implement ECM for the solenoid is shorted to ground. When this code
is generated, the lift linkage will not raise and the raise function will be
disabled until the fault is corrected and the levers are centered.
0007 00-35