TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0487 01
Position Sensor
This diagnostic code is recorded when the implement ECM determines
(Auxiliary Lever) Data
that the signal for the auxiliary lever position sensor is too low. The
Valid but Below Normal
auxiliary lever position sensor is a 500 Hz pulse width modulated
Operating Range
sensor. The possible causes for this diagnostic code are the auxiliary
lever sensor needs recalibrated. The signal circuit is shorted to ground.
When this code is generated, the auxiliary function will not operate and
the auxiliary lever must be recentered before movement of the auxiliary
function is allowed.
0487 03
Position Sensor
This diagnostic code is recorded when the ECM reads the voltage of
(Auxiliary Lever)
the circuit for the position sensor as being above normal. The signal
Voltage Above Normal
wire for the position sensor connects to connector contact J2-26 (wire
or Shorted High
H722 GN) of the ECM. The auxiliary lever position sensor is a 500 Hz
PWM sensor. The causes for this diagnostic code are:
The signal circuit is shorted to the +battery
circuit.
The sensor has failed.
The signal circuit is open.
The ground circuit is open.
When this code is generated, the auxiliary function will be disabled until
the diagnostic code is cleared and the lever must be recentered.
This diagnostic code is recorded when the implement ECM determines
0487 04
Position Sensor
that the voltage for the auxiliary lever position sensor is too low. The
(Auxiliary Lever)
auxiliary lever position sensor is a pulse width modulated sensor. The
Voltage Below Normal
possible causes for this diagnostic code are the harness between the
or Shorted Low
ECM and the sensor has a short, the sensor has failed, and the + battery
circuit has an open. When this code is generated, the auxiliary function
will be disabled until the diagnostic code is cleared and the auxiliary
lever must be centered.
0007 00-40