TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0357 03
Tilt Back Pilot Control
This diagnostic code is recorded when the ECM detects a short to the
Valve Solenoid 1
+battery in the electrical path that goes from the ECM to the solenoid
Voltage Above Normal
back to the ECM. The possible causes for this diagnostic code are the
or Shorted High
signal circuit from the ECM to the solenoid is shorted to the +battery
and the return circuit from the solenoid is shorted to the +battery. When
this code is generated, all electro-hydraulic valves are turned off, the
pilot on/off solenoid valve is turned off, and implement functions are
disabled until the fault is corrected and the levers are centered.
0357 05
Tilt Back Pilot Control
This diagnostic code is recorded when the ECM detects an incomplete
Valve Solenoid 1 Current
electrical path. The electrical path from the ECM to the solenoid back
Below Normal or Open
to the ECM is incomplete. The possible causes for this diagnostic code
Circuit
are:
The signal circuit from the ECM to the sole-
noids is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the tilt linkage will not tilt back, the
tiltback detent coil will be disabled, and the implements will be disabled
until the fault is corrected and the levers are centered.
0357 06
Tilt Back Pilot Control
This diagnostic code is recorded when the ECM detects a short to
Valve Solenoid 1 Current
ground in the electrical path from the ECM to the solenoid. The possible
Above Normal or
causes for this diagnostic code are, the internal windings for the
Grounded Circuit
solenoid have low impedance, the internal windings for the solenoid
are shorted, and the signal circuit from the ECM to the solenoid is
shorted to ground. When this code is generated, the tilt linkage will not
tilt back, the tilt back detent coil will be disabled, and the implements
will be disabled until the fault is corrected and the levers are centered.
0357 13
Tilt Back Pilot Control
This diagnostic code is recorded when the implement ECM determines
Valve Solenoid 1 Out of
Calibration
this diagnostic code are new software has been flashed and the
calibration of the valve has failed. When this code is generated, the
implement features will not operate efficiently.
0358 03
Pilot On/Off Control
This diagnostic code is recorded when the ECM detects a short to the
Valve Solenoid Voltage
+battery in the electrical path that goes from the ECM to the solenoid
Above Normal or
back to the ECM. The possible causes for this diagnostic code are the
Shorted High
signal circuit from the ECM to the solenoid is shorted to the +battery
and the return circuit from the solenoid is shorted to the +battery. When
this code is generated, the implement hydraulic operation is derated by
the implement ECM.
0007 00-38