TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0355 13
Lower Pilot Control
This diagnostic code is recorded when the implement ECM determines
Valve Solenoid 1 Out of
Calibration
diagnostic code are new software has been flashed and the calibration
of the valve has failed. When this code is generated, the implement
features will not operate efficiently.
0356 03
Dump Pilot Control
This diagnostic code is recorded when the ECM detects a short to the
Valve Solenoid 1
+battery in the electrical path that goes from the ECM to the solenoid
Voltage Above Normal
back to the ECM. The possible causes for this diagnostic code are the
or Shorted High
signal circuit from the ECM to the solenoid is shorted to the +battery
and the return circuit from the solenoid is shorted to the +battery. When
this code is generated, all electro-hydraulic valves are turned off, the
pilot on/off solenoid valve is turned off, and implement functions are
disabled until the fault is corrected and the levers are centered.
0356 05
Dump Pilot Control
This diagnostic code is recorded when the ECM detects an incomplete
Valve Solenoid 1 Current
electrical path. The electrical path from the ECM to the solenoid back
Below Normal or Open
to the ECM is incomplete. The possible causes for this diagnostic code
Circuit
are:
The signal circuit from the ECM to the sole-
noids is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the tilt linkage will not dump and the
implements will be disabled until the fault is corrected and the levers
are centered.
This diagnostic code is recorded when the ECM detects a short to
0356 06
Dump Pilot Control
ground in the electrical path from the ECM to the solenoid. The possible
Valve Solenoid 1 Current
causes for this diagnostic code are the internal windings for the solenoid
Above Normal or
have low impedance, the internal windings for the solenoid are shorted,
Grounded Circuit
and the signal circuit from the ECM to the solenoid is shorted to ground.
when this code is generated, the tilt linkage will not dump and the
implements will be disabled until the fault is corrected and the levers
are centered.
This diagnostic code is recorded when the implement ECM determines
0356 13
Dump Pilot Control
Valve Solenoid 1 Out of
Calibration
diagnostic code are new software has been flashed and the calibration
of the valve has failed. When this code is generated, the implement
features will not operate efficiently.
0007 00-37