TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0354 13
Lift Pilot Control Valve
This diagnostic code is recorded when implement ECM determines that
Solenoid 1 Out of
Calibration
diagnostic code are new software has been flashed and the calibration
of the valve has failed. When this code is generated, the implement
features will not operate efficiently.
0355 03
Lower Pilot Control
This diagnostic code is recorded when the implement ECM detects a
Valve Solenoid 1
short to the +battery in the electrical path that goes from the implement
Voltage Above Normal
ECM to the solenoid back to the implement ECM. The possible causes
or Shorted High
for this diagnostic code are the signal circuit from the implement ECM
to the solenoid is shorted to the +battery and the return circuit from the
solenoid is shorted to the +battery. When this code is generated, all
electro-hydraulic valves are turned off, the pilot on/off solenoid valve
is turned off, and implement functions are disabled until the fault is
corrected and the levers are centered.
0355 05
Lower Pilot Control
This diagnostic code is recorded when the implement ECM detects a
Valve Solenoid 1 Current
incomplete electrical path. The electrical path from the implement ECM
Below Normal Or Open
to the solenoid and back to the implement ECM is incomplete. The
Circuit
possible causes for this diagnostic code are:
The signal circuit fom the implement ECM
r
to the solenoids is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the lift linkage will not lower, the lower
detent coil will be disabled, and the implements will be disabled until
the fault is corrected and the levers are centered.
0355 06
Lower Pilot Control
This diagnostic code is recorded when the implement ECM detects a
Valve Solenoid 1 Current
short to ground in the electrical path from the implement ECM to the
Above Normal or
solenoid. The possible causes for this diagnostic code are the internal
Grounded Circuit
windings for the solenoid have low impedance, the internal windings
for the solenoid are shorted, and the signal circuit from the implement
ECM to the solenoid is shorted to ground. When this code is generated,
the lift linkage will not lower, the lower detent coil will be disabled,
and the implements will be disabled until the fault is corrected and the
levers are centered.
0007 00-36