TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 3. MID 082 Implement - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
0358 05
Pilot On/Off Control
This diagnostic code is recorded when the ECM detects an incomplete
Valve Solenoid Current
electrical path. The electrical path from the ECM to the solenoid back
Below Normal or Open
to the ECM is incomplete. The possible causes for this diagnostic code
Circuit
are:
The signal circuit from the ECM to the sole-
noids is open.
The return circuit from the solenoid is open.
The internal windings for the solenoid have
The internal windings for the solenoid are
open.
When this code is generated, the implement features do not function
and the pilot on/ off solenoid valve will not operate.
0358 06
Pilot On/Off Control
This diagnostic code is recorded when the ECM detects a short to
Valve Solenoid Current
ground in the electrical path from the ECM to the solenoid. The possible
Above Normal or
causes for this diagnostic code are the internal windings for the solenoid
Grounded Circuit
have low impedance, the internal windings for the solenoid are shorted,
the signal circuit from the ECM to the solenoid is shorted to ground.
When this code is generated, the implement features will not operate
and the pilot on/ off solenoid valve is OFF.
0365 04
Lift, Lower and Bucket
This switch has two inputs to the ECM. Both inputs are normally open.
Kickout Set Switch
During proper operation, both inputs are normally open. This diagnostic
Voltage Below Normal
code is recorded when the status of both the inputs are grounded. The
or Shorted Low
possible causes of this diagnostic code are:
Both inputs are shorted to ground in the har-
ness.
Both inputs are shorted together. The switch
must be in one specific position.
The switch has failed.
When this code is generated, the switch will not change the kickout
position.
0487 00
Position Sensor
This diagnostic code is recorded when the ECM determines that the
(Auxiliary Lever) Data
signal from the auxiliary lever position sensor is out of location. The
Valid but Above Normal
auxiliary lever position sensor is a 500 Hz PWM sensor. The possible
Operating Range
cause for this diagnostic code is the auxiliary lever position sensor needs
recalibrated. When this code is generated, if the diagnostic code is
active for at least three seconds, then the 487-13 diagnostic code will
become active. The 487-00 diagnostic code will become inactive.
0007 00-39